TM 9-2320-386-24-1-1
0242 00
PERSONNEL HOT WATER HEATER CONTROL CABLES REPLACEMENT (Contd)
REMOVAL
1.
Loosen screw (3) and clamp (2) on water shutoff valve (5).
2.
Disconnect damper control cable (1) from lever (4) and remove from clamp (2) and water shutoff
valve (5).
3.
Remove grommet (9) and damper control cable (1) from firewall (6).
4.
Loosen screw (17) and clamp (18) on diverter (19).
5.
Disconnect defroster control cable (12) from shaft lever (20) and remove defroster control cable (12)
from diverter (19) and clamp (18).
6.
Remove two nuts (7), lockwashers (8), screws (14), and bracket (13) from instrument panel (21).
Discard lockwashers (8).
7.
Remove nut (10), lockwasher (11), and damper control cable (1) from bracket (13). Discard
lockwasher (11).
8.
Remove nut (16), lockwasher (15), and defroster control cable (12) from bracket (13). Discard
lockwasher (15).
INSTALLATION
1.
Insert defroster control cable (12) through bracket (13) and install with new lockwasher (15) and
nut (16).
2.
Insert damper control cable (1) through bracket (13) and install with new lockwasher (11) and
nut (10).
3.
Install bracket (13) on instrument panel (21) with two screws (14), new lockwashers (8), and
nuts (7).
4.
Insert defroster control cable (12) through clamp (18) and install on shaft lever (20).
5.
Tighten screw (17) and clamp (18) on diverter (19).
6.
Install grommet (9) on damper control cable (1) and hole in firewall (6).
7.
Insert damper control cable (1) through hole in firewall (6).
8.
Route damper control cable (1) to water shutoff valve (5) and install on lever (4).
9.
Tighten screw (3) and clamp (2) on damper control cable (1).
0242 00-2
|