TM 9-2320-386-24-1-1
0222 00
FRONT WINCH HYDRAULIC PUMP REPLACEMENT (Contd)
REMOVAL
CAUTION
Plug all openings immediately after disconnecting hoses and
fittings to prevent dirt and dust from entering hydraulic system.
Contamination of the hydraulic system may result damage to
equipment. Remove plugs before installation.
1.
Disconnect leads 25 and 26 (5) from air solenoid (6).
WARNING
Do not disconnect air lines before draining air reservoirs. Small
parts under pressure may shoot out with high velocity, causing
injury to personnel.
Eyeshields must be worn when releasing compressed air. Failure
to do this may result in injury to personnel.
2.
Disconnect air line (9) from elbow (4).
3.
Remove two nuts (1), washers (2), screws (7), and air horns (8) from mounting bracket (3).
NOTE
Have drainage container ready to catch oil.
4.
Remove hose connector (17) from fitting (16).
5.
Remove hose connector (18) from elbow (19).
6.
Remove fitting (16) from elbow (15).
7.
Remove elbow (15) and O-ring (14) from pump (13). Discard O-ring (14).
8.
Remove two screws (12), lockwashers (11), pump (13), and gasket (10) from air compressor (21).
Discard lockwashers (11) and gasket (10).
9.
Remove elbow (19) and O-ring (20) from pump (13). Discard O-ring (20).