Click here to make tpub.com your Home Page

Page Title: FRONT WINCH HYDRAULIC SYSTEM SERVICING - continued
Back | Up | Next

Click here for a printable version

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

TM 9-2320-386-24-1-1
0213 00
FRONT WINCH HYDRAULIC SYSTEM SERVICING (Contd)
DRAIN SYSTEM
WARNING
Accidental or intentional introduction of liquid contaminants into
the environment is in violation of state, federal, and military
regulations. Refer to Army POL (WP 0001 00) for information
concerning storage, use, and disposal of these liquids. Failure to
do so may result in injury or death.
NOTE
Have drainage container ready to catch oil.
1.
Remove cap (1) from lockplate (2).
2.
Remove drainplug (4) and gasket (5) from reservoir (3). Discard gasket (5).
NOTE
Allow reservoir to drain completely before performing step 3.
3.
Inspect sight glass (6). Replace if damaged.
4.
Install new gasket (5) and drainplug (4) on reservoir (3).
5.
Install cap (1) on lockplate (2).
FILL SYSTEM
1.
Remove cap (1) from lockplate (2).
NOTE
Correct oil level can be verified by checking the sight glass.
2.
Add oil (WP 0023 00) to reservoir (3), filling system until oil level is centered in sight glass (6).
3.
Install cap (1) on lockplate (2).
4.
Operate winch (TM 9-2320-386-10), as follows:
a. Unwind cable 32-48 ft (10-15 m).
b. Rewind and stow cable.
5.
Add oil to reservoir (3) to obtain correct oil level, if necessary.
0213 00-2

Privacy Statement - Press Release - Copyright Information. - Contact Us

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business