0176 00
CTIS WHEEL VALVE AND FILTER MAINTENANCE (Contd)
REMOVAL
WARNING
Do not disconnect air lines and fittings before draining reservoirs.
Small parts under pressure may shoot out with high velocity,
causing injury to personnel.
Eyeshields must be worn when releasing compressed air. Failure
to do so may result in injury to personnel.
NOTE
Front and rear wheel valve assemblies are replaced basically
the same. This procedure covers the left front wheel valve.
Tag all hoses, lines, and tubes for installation.
1.
Remove cap (2) from wheel valve stem (4) and drain air from tire. Install cap (2) on wheel valve (4).
2.
Remove two nuts (21), screws (23), lockwashers (22), and stone shield (1) from wheel (13). Discard
3.
Remove air line (5) from elbow (3) and connector (7).
4.
Remove air line (18) from elbow (19) and connector (17).
5.
Remove two nuts (8) and mounting plate (10) from wheel (13).
6.
Remove four locknuts (6), screws (11), and wheel valve (20) from mounting plate (10). Discard
locknuts (6).
7.
Remove elbows (3) and (19) from wheel valve (20).
8.
Remove in-line filter (16) and connector (17) from elbow (15).
9.
Remove connector (7) from elbow (9).
10.
Remove elbows (9) and (15) from hollow stud (12) and turret valve (14).
IN-LINE FILTER CLEANING AND INSPECTION
WARNING
Skysol-100 mixture is combustible. Use mechanical ventilation whenever
product is used in a confined space, is heated above ambient
temperatures, or is agitated. DO NOT use or store near heat, sparks,
flame, or other ignition sources. Keep container sealed when not in use.
Contact with Skysol-100 may cause skin irritation. Use chemical resistant
gloves. In case of skin contact, remove any contaminated clothing and
wash skin thoroughly with soap and water. Wash contaminated clothing
before reuse. Eye contact may cause irritation, tearing, or blurring of
vision. Use face shield or goggles when eye contact may occur. In case of
eye contact, flush eyes with large amounts of water for at least fifteen
(15) minutes or until irritation subsides. Inhalation may cause irritation
to upper respiratory passages. DO NOT have food or drink in the vicinity.
1.
Inspect in-line filter (16) for dirt, oil, debris, and other contaminants.
2.
Clean in-line filter (16) in Skysol-100 and air dry.