TM 9-2320-386-24-1-1
0167 00
COMPRESSED AIR LINES REPLACEMENT AND REPAIR (Contd)
NOTE
As a general rule, due to repairs, an air tube may have up to two
connectors installed on its length between end-points. Air tubes
that require additional repair should be replaced.
Refer to WP 0385 00 for tubing application and tightening
instructions.
DAMAGE AT ENDPOINT
NOTE
Damage to the air tube can hamper the locking capability of the
fitting. After connecting and installing fittings and air tubes, test
for possible damage at end point of the air tube, or damage to the
fitting may result.
1.
Test lock as follows:
a. Tighten fitting (1).
b. Placing hand close to fitting (1), attempt to pull tube (2) free from fitting (1). If tube (2) is
removed from fitting (1), repair tube (2).
2.
Repair tube (2) as follows:
a. Cut tube (2) so that locking surface (3) is free from damage. Discard damaged section (4).
NOTE
A click indicates tube passing the internal O-ring, locking the
air tube into the fitting.
b. Insert tube (2) into fitting (1).
3.
Test lock by attempting to pull tube (2) free from fitting (1). If tube (2) is removed from fitting (1),
replace fitting (1).
DAMAGE AT POINT BETWEEN FITTINGS
1.
Cut tube (5) at locations (6). Discard damaged section (7).
2.
Install connector (9) on tubes (5) and (8).
0167 00-2
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |