0160 00
PROPORTIONAL VALVE REPLACEMENT (Contd)
REMOVAL
1.
Remove two screws (10), lockwashers (11), and skid plate (12) from air hydraulic booster (14).
Discard lockwashers (11).
2.
Disconnect wiring harness lead 116 (5) from proportional valve (7).
CAUTION
Cap or plug all tubes, connections, and openings immediately
after disconnection to prevent contamination. Failure to do so may
result in damage to equipment. Remove all plugs prior to
installation.
NOTE
Have drainage container ready to catch brake fluid.
3.
Disconnect tube (2) from proportional valve (7).
4.
Disconnect tube (13) from proportional valve (7).
5.
Disconnect tube (4) from proportional valve (7).
6.
Disconnect tube (6) from proportional valve (7).
7.
Remove two locknuts (9), washers (8), capscrews (1), and proportional valve (7) from bracket (3).
Discard locknuts (9).
INSTALLATION
1.
Install proportional valve (7) on bracket (3) with two capscrews (1), washers (8), and new
locknuts (9). Tighten locknuts (9) to 11 lb-ft (15 Nm).
2.
Connect tube (6) to proportional valve (7).
3.
Connect tube (4) to proportional valve (7).
4.
Connect tube (13) to proportional valve (7).
5.
Connect tube (2) to proportional valve (7).
6.
Connect wiring harness lead 116 (5) to proportional valve (7).
7.
Install skid plate (12) on air hydraulic booster (14) with two new lockwashers (11) and screws (10).
8.
Connect battery ground cable (WP 0121 00).
9.
Bleed service brakes (WP 0154 00).