TM 9-2320-386-24-1-1
0151 00
AXLE BREATHER MAINTENANCE (Contd)
NOTE
Front and rear axle housing breathers are maintained the same.
This procedure covers the front axle housing breather.
REMOVAL
Remove breather (1) from axle housing (2).
CLEANING
.WARNING.
Skysol-100 mixture is combustible. Use mechanical ventilation whenever
product is used in a confined space, is heated above ambient
temperatures, or is agitated. DO NOT use or store near heat, sparks,
flame, or other ignition sources. Keep container sealed when not in use.
Contact with Skysol-100 may cause skin irritation. Use chemical resistant
gloves. In case of skin contact, remove any contaminated clothing and
wash skin thoroughly with soap and water. Wash contaminated clothing
before reuse. Eye contact may cause irritation, tearing, or blurring of
vision. Use face shield or goggles when eye contact may occur. In case of
eye contact, flush eyes with large amounts of water for at least fifteen (15)
minutes or until irritation subsides. Inhalation may cause irritation to
upper respiratory passages. DO NOT have food or drink in the vicinity.
Clean breather (1) with Skysol-100 and dry with clean rag.
INSTALLATION
1.
Apply sealant to male threads of breather (1).
2.
Install breather (1) on axle housing (2).
1
2
END OF WORK PACKAGE