TM 9-2320-386-24-1-1
0147 00
PROPELLER SHAFT MAINTENANCE (Contd)
REMOVAL
NOTE
All propeller shafts, except the M36A3 front intermediate
propeller shaft, are replaced basically the same. This procedure
covers the transfer case-to-forward rear axle propeller shaft.
1.
Chock two wheels on one side of vehicle and raise two wheels on opposite side of vehicle
(TM 9-2320-386-10).
2.
Release parking brake (TM 9-2320-386-10).
NOTE
Mark propeller shaft flange positions for installation.
Rotate propeller shaft to gain access to propeller shaft mounting
screws and locknuts.
3.
Remove four locknuts (5) from studs (2) and separate flange (4) on propeller shaft (10) from
flange (1) located in parking brakedrum (3). Discard locknuts (5).
4.
Remove four locknuts (9) and screws (6) and seperate flange (7) on propeller shaft (10)P from
flange (8). Discard locknuts (9).
DISASSEMBLY
1.
Loosen cap (15) and slide back on shaft (16).
2.
Pull shaft (16) out of washer (14), seal (13), and tube of shaft (12).
3.
Remove washer (14) and seal (13) from shaft (12). Discard seal (13).
NOTE
Perform step 4 or 5 if lubrication fitting is damaged.
4.
Remove lubrication fitting (18) from shaft (12).
5.
Remove lubrication fitting (11) from U-joint end of shaft (12).
CLEANING AND INSPECTION
1.
Inspect U-joint for roughness, binding, looseness, and free play. Replace U-joint if there is any
roughness, binding, looseness, or free play (WP 0149 00).
WARNING
Skysol-100 mixture is combustible. Use mechanical ventilation whenever
product is used in a confined space, is heated above ambient
temperatures, or is agitated. DO NOT use or store near heat, sparks,
flame, or other ignition sources. Keep container sealed when not in use.
Contact with Skysol-100 may cause skin irritation. Use chemical
resistant gloves. In case of skin contact, remove any contaminated
clothing and wash skin thoroughly with soap and water. Wash
contaminated clothing before reuse. Eye contact may cause irritation,
tearing, or blurring of vision. Use face shield or goggles when eye contact
may occur. In case of eye contact, flush eyes with large amounts of water
for at least fifteen (15) minutes or until irritation subsides. Inhalation
may cause irritation to upper respiratory passages. DO NOT have food or
drink in the vicinity.
2.
Clean splined end of shaft (16) with rag saturated with Skysol-100. Dry with clean rag.
3.
Clean bore (17) of shaft (12) with Skysol-100. Clean outside of shaft (12) with rag saturated with
Skysol-100.
0147 00-2
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |