TM 9-2320-386-24-1-1
0124 00
STE/ICE-R SHUNT REPLACEMENT (Contd)
REMOVAL
1.
Remove screw (2), lockwasher (3), terminal with leads 770Y and 770W (18) and terminal 770F (17),
and washer (16) from STE/ICE-R shunt (14). Discard lockwasher (3).
2.
Remove screw (4), lockwasher (8), terminal 770X (9), and washer (10) from STE/ICE-R shunt (14).
Discard lockwasher (8).
3.
Remove screw (1), lockwasher (20), and terminal 7A (19) from STE/ICE-R shunt (14). Discard lock-
washer (20).
4.
Remove screw (5), lockwasher (6), and terminal 7 (7) from STE/ICE-R shunt (14). Discard lock-
washer (7).
5.
Remove two locknuts (12), washers (11), screws (15), and STE/ICE-R shunt (14) from mounting
bracket (13). Discard locknuts (12).
INSTALLATION
1.
Install STE/ICE-R shunt (14) on mounting bracket (13) with two screws (15), washers (11), and new
locknuts (12).
2.
Install terminal 7 (7), new lockwasher (6), and screw (5) on STE/ICE-R shunt (14).
3.
Install terminal 7A (19), new lockwasher (20), and screw (1) on STE/ICE-R shunt (14).
4.
Install washer (10), terminal 770X (9), new lockwasher (8), and screw (4) on STE/ICE-R shunt (14).
5.
Install washer (16), terminals with leads 770Y and 770W (18) and terminal 770F (17), new
lockwasher (3), and screw (2) on STE/ICE-R shunt (14).
6.
Connect battery ground cable (WP 0121 00).
0124 00-2
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |