TM 9-2320-386-24-1-1
0118 00
LOW AIR PRESSURE SWITCH REPLACEMENT (Contd)
WARNING
Eyeshields must be worn when releasing compressed air. Failure
to do this may result in injury to personnel.
Do not disconnect air lines before draining air reservoirs. Small
parts under pressure may shoot out with high velocity, causing
injury to personnel.
CAUTION
When disconnecting air lines and hoses, plug all openings to
prevent dirt from entering and causing damage to internal parts.
Remove plugs prior to installation.
REMOVAL
NOTE
Tag all wires for installation.
1.
Turn four lockstuds (3) 1/4-turn to left and pull instrument mounting panel (2) away from
instrument panel (1).
2.
Disconnect two leads 85 and 85A (6) from low air pressure switch (4).
3.
Remove low air pressure switch (4) from tube and hose manifold (5).
INSTALLATION
1.
Apply sealant to male threads of low air pressure switch (4).
2.
Install low air pressure switch (4) on tube and hose manifold (5).
3.
Connect two leads 85 and 85A (6) to low air pressure switch (4).
4.
Position instrument mounting panel (2) to instrument panel (1) and install by turning four
lockstuds (3) 1/4-turn to right.
5.
Connect battery ground cable (WP 0121 00).
6.
Start engine (TM 9-2320-386-10) and check low air pressure switch operation.