TM 9-2320-386-24-1-1
0096 00
TRANSMISSION OIL TEMPERATURE GAUGE REPLACEMENT (Contd)
NOTE
Appropriate locking hardware is provisioned with gauge.
REMOVAL
1.
Disconnect leads 27 and 324 (2) from gauge (1).
2.
Remove two nuts (7), lockwashers (6), ground (GND) terminal (5), mounting bracket (4), and
gauge (1) from instrument panel (3).
INSTALLATION
1.
Install gauge (1) on instrument panel (3) with mounting bracket (4), ground (GND) terminal (5),
two lockwashers (6), and nuts (7).
2.
Connect leads 27 and 324 (2) to gauge (1).
3.
Connect battery ground cable (WP 0121 00).