Page Title: WATER PUMP REPLACEMENT - continued
Back | Up | Next

Click here for a printable version

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

TM 9-2320-386-24-1-1
0080 00
WATER PUMP REPLACEMENT (Contd)
REMOVAL
1.
Using a breaker bar, rotate belt tensioner (4) counterclockwise to relieve belt tension.
NOTE
Crankshaft pulley is located behind vibration damper.
2.
Remove fan drivebelt (2) from alternator pulley (5), crankshaft pulley (3), and fan pulley (1).
3.
Release belt tensioner (4).
NOTE
Vehicles may come equipped with a Leece-Neville or Prestolite
alternator. STE/ICE-R wiring harness leads are connected to
negative and positive posts on either alternator.
4.
Remove screw (9), lockwasher (8), ground (GND) terminal lead (7), and STE/ICE-R terminal
lead 770-P (18) from alternator (17). Discard lockwasher (8).
NOTE
Perform steps 5 and 6 for Prestolite alternators only.
Perform step 7 for Leece-Neville alternators only.
5.
Remove two screws (6), lockwashers (22), and plate (21) from alternator (17). Discard
lockwashers (22).
6.
Remove two assembled-washer screws (11) and cover plate (10) from alternator (17). Discard
assembled-washer screws (11).
7.
Remove two screws (23), lockwashers (24), and cover plate (10) from alternator (17). Discard
lockwashers (24).
8.
Remove nut (12), lockwasher (13), positive lead 2 (14), and STE/ICE-R terminal lead 770-N (15)
from stud (16). Discard lockwasher (13).
9.
Disconnect lead 568 (21) from Y-connector (20).
0080 00-2