TM 9-2320-386-24-1-1
0080 00
WATER PUMP REPLACEMENT (Contd)
REMOVAL
1.
Using a breaker bar, rotate belt tensioner (4) counterclockwise to relieve belt tension.
NOTE
Crankshaft pulley is located behind vibration damper.
2.
Remove fan drivebelt (2) from alternator pulley (5), crankshaft pulley (3), and fan pulley (1).
3.
Release belt tensioner (4).
NOTE
Vehicles may come equipped with a Leece-Neville or Prestolite
alternator. STE/ICE-R wiring harness leads are connected to
negative and positive posts on either alternator.
4.
Remove screw (9), lockwasher (8), ground (GND) terminal lead (7), and STE/ICE-R terminal
lead 770-P (18) from alternator (17). Discard lockwasher (8).
NOTE
Perform steps 5 and 6 for Prestolite alternators only.
Perform step 7 for Leece-Neville alternators only.
5.
Remove two screws (6), lockwashers (22), and plate (21) from alternator (17). Discard
lockwashers (22).
6.
Remove two assembled-washer screws (11) and cover plate (10) from alternator (17). Discard
assembled-washer screws (11).
7.
Remove two screws (23), lockwashers (24), and cover plate (10) from alternator (17). Discard
lockwashers (24).
8.
Remove nut (12), lockwasher (13), positive lead 2 (14), and STE/ICE-R terminal lead 770-N (15)
from stud (16). Discard lockwasher (13).
9.
Disconnect lead 568 (21) from Y-connector (20).
0080 00-2
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |