QUICK-START TUBES REPLACEMENT (BUILT BEFORE SERIAL NO. 504924) (Contd)
.WARNING.
Ether is extremely flammable. Perform this procedure in a well-
ventilated area away from flames and sparks. Failure to do so
may result in injury to personnel.
REMOVAL
1.
Loosen two nuts (2) and remove tubes (1) with sleeves (3) from atomizers (4).
2.
Loosen two nuts (11) and remove tubes (1) with sleeves (12) from atomizer tee (13).
3.
Loosen two nuts (9) and remove tube (10) with sleeves (8) from atomizer tee (13) and elbow (7).
4.
Remove locknut (6), screw (15), clamp (14), and atomizer tee (13) from mounting bracket (5). Discard
locknut (6).
INSTALLATION
1.
Install tube (10) with sleeves (8) on atomizer tee (13) and elbow (7) and tighten nuts (9).
2.
Install two tubes (1) with sleeves (12) on atomizer tee (13) and tighten nuts (11).
3.
Install two tubes (1) with sleeves (3) on atomizers (4) and tighten nuts (2).
4.
Install atomizer tee (13) on mounting bracket (5) with clamp (14), screw (15), and new locknut (6).