TM 9-2320-386-24-1-1
0055 00
QUICK-START CYLINDER AND VALVE REPLACEMENT (BUILT BEFORE SERIAL NO. 504924) (Contd)
.WARNING.
Ether is extremely flammable. Perform this procedure in a well-
ventilated area away from flames and sparks. Failure to do so
may result in injury to personnel.
REMOVAL
1.
Loosen wingnut (1) and clamp (2) on cylinder (15).
2.
Remove (turn counterclockwise) cylinder (15) from quick-start valve (9) and remove from clamp (2).
3.
Remove gasket (11) from quick-start valve (9) if cracked or damaged.
4.
Install plug with chain (13) on quick-start valve (9).
5.
Disconnect harness plug with leads 569A and 569B (7) from quick-start valve lead connector (8).
6.
Loosen nut (4) and remove tube (6) with sleeve (5) from elbow (10).
7.
Remove two screws (12), plug with chain (13), clamp (14), and quick-start valve (9) from bracket (3).
NOTE
Note position of elbow for installation.
8.
Remove elbow (10) from quick-start valve (9).
INSTALLATION
1.
Apply sealant to threads of elbow (10) and install elbow (10) on quick-start valve (9).
2.
Install quick-start valve (9), clamp (14), and plug with chain (13) on bracket (3) with two
screws (12).
3.
Install tube (6) with sleeve (5) on elbow (10) and tighten nut (4).
4.
Remove plug with chain (13) from quick-start valve (9) and install plug with chain (13) on
clamp (14).
5.
If removed, install new gasket (11) on quick-start valve (9).
6.
Insert cylinder (15) through clamp (2) and install (turn clockwise) on quick-start valve (9). Tighten
wingnut (1) and clamp (2) on cylinder (15).
7.
Connect harness plug with leads 569A and 569B (7) to quick-start valve lead connector (8).
8.
Connect battery ground cable (WP 0121 00).
0055 00-2
|