TM 9-2320-386-24-1-1
0041 00
AIR CLEANER INDICATOR AND TUBE MAINTENANCE (Contd)
CLEANING AND INSPECTION
1.
Inspect tube (5) for kinks and obstruction. Replace tube (5) if kinked or obstructed.
.WARNING.
Compressed air used for cleaning purposes will not exceed 30 psi
(207 kPa). Use only with effective chip guarding and personal
protective equipment (goggles/shields, gloves, etc.).
2.
Clean tube (5) by blowing compressed air through tube (5).
INSTALLATION
1.
Apply sealant to male threads of adapter (3) and stud (2) of air cleaner (1).
2.
Install adapter (3) on stud (2) of air cleaner (1).
3.
Connect tube (5) to adapter (3).
4.
Route tube (5) from air cleaner (1) through clamps (4) and (6), insert through cab (7), and install
grommet (8). Tighten clamps (4) and (6).
5.
Install adapter (13) on air cleaner indicator (12).
6.
Install air cleaner indicator (12) on bracket (10) with two screws (11) and nuts (9).
7.
Connect tube (5) to adapter (13).
0041 00-4
|