TM 9-2320-386-24-1-1
0040 00
AIR CLEANER ELEMENT MAINTENANCE (Contd)
.WARNING.
If NBC exposure is suspected, all air filtering media should be
handled by personnel wearing protective equipment. Consult
your unit NBC officer or NBC NCO for appropriate handling or
disposal instructions.
NBC contaminated air cleaner elements must be handled using
adequate precautions (FM 21-40) and must be disposed of by
trained personnel.
REMOVAL
1.
Loosen wingnut (8) and remove cover (1) and gasket (3) from air cleaner (5). Discard gasket (3).
2.
Remove clip (2), wingnut (8), and gasket (7) from cover (1). Discard gasket (7).
3.
Remove wingnut (4) and air cleaner element (6) from air cleaner (5). Clean or discard air cleaner
element (6).
SERVICE
.WARNING.
Compressed air used for cleaning purposes will not exceed 30 psi
(207 kPa). Use only with effective chip guarding and personal
protective equipment (goggles/shields, gloves, etc.).
Clean air cleaner element (6) by tapping lightly, or use compressed air to loosen and remove dirt.
Replace air cleaner element (6) if necessary.
INSTALLATION
1.
Install new air cleaner element (6) or cleaned air cleaner element (6) in air cleaner (5) with
wingnut (4).
2.
Install new gasket (7) and wingnut (8) on cover (1) with clip (2).
3.
Install new gasket (3) and cover (1) on air cleaner (5) and tighten wingnut (8).
4
3
2
1
5
7
8
6
END OF WORK PACKAGE
0040 00-2
|