Click here to make tpub.com your Home Page

Page Title: AIR CLEANER ELEMENT MAINTENANCE - continued
Back | Up | Next

Click here for a printable version

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

TM 9-2320-386-24-1-1
0040 00
AIR CLEANER ELEMENT MAINTENANCE (Contd)
.WARNING.
If NBC exposure is suspected, all air filtering media should be
handled by personnel wearing protective equipment. Consult
your unit NBC officer or NBC NCO for appropriate handling or
disposal instructions.
NBC contaminated air cleaner elements must be handled using
adequate precautions (FM 21-40) and must be disposed of by
trained personnel.
REMOVAL
1.
Loosen wingnut (8) and remove cover (1) and gasket (3) from air cleaner (5). Discard gasket (3).
2.
Remove clip (2), wingnut (8), and gasket (7) from cover (1). Discard gasket (7).
3.
Remove wingnut (4) and air cleaner element (6) from air cleaner (5). Clean or discard air cleaner
element (6).
SERVICE
.WARNING.
Compressed air used for cleaning purposes will not exceed 30 psi
(207 kPa). Use only with effective chip guarding and personal
protective equipment (goggles/shields, gloves, etc.).
Clean air cleaner element (6) by tapping lightly, or use compressed air to loosen and remove dirt.
Replace air cleaner element (6) if necessary.
INSTALLATION
1.
Install new air cleaner element (6) or cleaned air cleaner element (6) in air cleaner (5) with
wingnut (4).
2.
Install new gasket (7) and wingnut (8) on cover (1) with clip (2).
3.
Install new gasket (3) and cover (1) on air cleaner (5) and tighten wingnut (8).
4
3
2
1
5
7
8
6
END OF WORK PACKAGE
0040 00-2

Privacy Statement - Press Release - Copyright Information. - Contact Us

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business