TM 9-2320-386-24-1-1
0023 00
OIL FILTERS
Oil
filters shall be changed as applicable, when:
(1)
They are known to be contaminated or clogged.
(2)
Service is recommended by AOAP laboratory analysis:
(3)
Prescribed hard-time intervals are reached.
AOAP REQUIREMENTS
(1) Engine oil, transmission oil, and hydraulic fluids must be sampled at 60 days or 1,000 miles
(1,609 km). Reserve and National Guard units should perform oil sampling every 120 days or 1,000 miles
(1,609 km) as prescribed by TB 43-0106 Aeronautical Equipment Army Oil Analysis Program (AOAP), or
DA Pam 738-750, Functional User Guide for the Army Maintenance Management System (TAMMS).
(2) In the event AOAP laboratory support is not available, use on-condition (OC) hard-time intervals will
be applied.
CLEANING
.WARNING.
Skysol-100 mixture is combustible. Use mechanical ventilation
whenever product is used in a confined space, is heated above
ambient temperatures, or is agitated. DO NOT use or store near
heat, sparks, flame, or other ignition sources. Keep container
sealed when not in use.
Contact with Skysol-100 may cause skin irritation. Use chemical
resistant gloves. In case of skin contact, remove any contaminated
clothing and wash skin thoroughly with soap and water. Wash
contaminated clothing before reuse. Eye contact may cause
irritation, tearing, or blurring of vision. Use face shield or goggles
when eye contact may occur. In case of eye contact, flush eyes
with large amounts of water for at least fifteen (15) minutes or
until irritation subsides. Inhalation may cause irritation to upper
respiratory passages. DO NOT have food or drink in the vicinity.
Keep all lubricants in closed container and store in clean, dry
place, away from extreme heat. Failure to do so may result in
injury to personnel.
CAUTION
Keep container covers clean and allow no dust, dirt, or other
foreign material to mix with lubricants. Keep all lubrication
equipment clean and ready to use.
(1) Keep all external parts of equipment not requiring lubrication free of lubricants.
(2) Before lubricating equipment, clean fittings. Use a biodegradable Skysol-100 to wipe all lubrication
points free of dirt and grease and dry before lubricating. After servicing lubrication points, wipe off excess
lubricants to prevent accumulation of foreign matter.
0023 00-2
|