DIFFERENTIAL CARRIER REPLACEMENT (Contd)
WARNING
Accidental or intentional introduction of liquid contaminants
into the environment is a violation of state, federal, and military
regulations. Refer to Army POL (WP 0001 00) for information
concerning storage, use, and disposal of these liquids. Failure to
do so may result in damage to environment and health of
personnel.
CAUTION
Work area should be clean, well-ventilated, and free from
blowing dust and dirt. Damage to equipment could result if area
is not clean.
NOTE
Use a drain pan to capture any draining oil. Dispose of fluids in
accordance with local policy and ordinances. Ensure all spills
are cleaned up.
REMOVAL
1.
Remove drain plug (12) from bottom of housing (6) and drain gear oil.
2.
Remove eight nuts (1) and washers (2) from eight studs (3).
3.
Loosen four remaining nuts (10) on studs (8).
4.
Remove screw (5) and washer (4) from carrier (7).
5.
Install utility chains on carrier (7) with washer (4) and screw (5). Attach lifting device on utility
chains.
WARNING
All personnel must stand clear during lifting operations.
A swinging or shifting load may cause injury or death to
personnel.
CAUTION
When lifting differential carrier out of axle housing, use care
not to damage mounting studs.
NOTE
Assistant will help with steps 6 and 7.
6.
Using lifting device, raise carrier (7) 1/2 in. (1.3 cm) out of housing (6) and remove four remaining
nuts (10) and washers (9) from studs (8).
7.
Remove carrier (7) from housing (6).
8.
Remove gasket (11) from housing (6). Discard gasket (11).
9.
Lower carrier (7) to workbench and remove lifting device from utility chains.
10.
Remove screw (5), washer (4), and chains from carrier (7).
INSTALLATION
1.
Install chains on carrier (7) with washer (4) and screw (5).
2.
Install new gasket (11) on housing (6).
3.
Install lifting device on utility chain.