60-AMPERE ALTERNATOR REPAIR (Contd)
DISASSEMBLY (Contd)
7.
Scribe a locating mark (5) on end housing (2) and intermediate housing (1).
NOTE
Brush springs will fall free when end housing is removed from
intermediate housing.
8.
Remove six screws (4), lockwashers (3), and end housing (2) from intermediate housing (1). Discard
9.
Remove insulating compound from capacitor (6).
10.
Remove screw (18), nut (19), lockwasher (20), washer (21), and capacitor (6) from negative rectifier
plate (16) and output plate stud (11). Discard lockwasher (20).
11.
Remove two screws (12), lockwasher (17), two brush leads (13), and lead (15) from insulator (14)
and output strap (7). Discard lockwasher (17).
12.
Remove two brushes (24) and springs (23) from brush holder (26).
13.
Remove three screws (25), brush holder (26), insulator (14), and shim (22) from end housing (2).
14.
Remove screw (8), lockwasher (9), and output strap (7) from positive rectifier plate (10) and output
plate stud (11). Discard lockwasher (9).