60-AMPERE ALTERNATOR REPAIR (Contd)
NOTE
Prior to removal, tag lead wires for assembly.
DISASSEMBLY
1.
Remove access plug (7) from end housing (4).
2.
Remove six screws (1), end cover (2), and O-ring (3) from end housing (4). Discard O-ring (3).
NOTE
Regulator is part of end cover, do not disassemble.
3.
Disconnect three leads (10) from three terminals (11) on regulator (12).
4.
Remove two screw-assembled lockwashers (6) and output plate cover (5) from end housing (4).
Discard screw-assembled lockwashers (6).
5.
Remove sealer from three stator leads (8).
6.
Unsolder and disconnect three stator leads (8) from three stator lead terminals (9). Refer to
TC 9-237.
6
5
7
2
3
4
1
0448 00-2