PERSONNEL HEATER OVERHEAT SWITCH AND RECEPTACLE REPLACEMENT (Contd)
RECEPTACLE INSTALLATION
1.
Install receptacle (15) on bracket (8) with four new screw-assembled lockwashers (1).
2.
Install receptacle ground lead (14) on stud (9) with nut (4).
3.
Install leads (16) and (7) on flame detector switch (11) with new screw-assembled lockwashers (5)
and (6).
4.
Install receptacle lead (12) on overheat switch (10) with new nut-assembled lockwasher (13).
5.
Install restriction solenoid lead (3) on receptacle (15) with new screw-assembled lockwasher (2).
OVERHEAT SWITCH INSTALLATION
1.
Install overheat switch (21) on heater housing (19) with two screw-assembled lockwashers (20).
2.
Install ignition control lead (22), thermostat lead (23), and receptacle lead (24) on overheat
switch (21) with new nut-assembled lockwasher (25).
3.
Install shutoff valve lead (18) on overheat switch (21) with new nut-assembled lockwasher (17).
4.
Install personnel heater guard (WP 0427 00).
5.
Connect battery ground cable (WP 0126 00).
6.
Release parking brake and remove wheel chocks (TM 9-2320-361-10).