TM 9-2320-361-24-2
0433 00
PERSONNEL HEATER OVERHEAT SWITCH AND RECEPTACLE REPLACEMENT (Contd)
NOTE
Prior to removal, tag lead wires for installation.
OVERHEAT SWITCH REMOVAL
1.
Remove nut-assembled lockwasher (1) and shutoff valve lead (2) from overheat switch (5). Discard
nut-assembled lockwasher (1).
2.
Remove nut-assembled lockwasher (9), receptacle lead (8), thermostat lead (7), and ignition control
lead (6) from overheat switch (5). Discard nut-assembled lockwasher (9).
3.
Remove two screw-assembled lockwashers (4) and overheat switch (5) from heater housing (3).
Discard screw-assembled lockwashers (4).
RECEPTACLE REMOVAL
1.
Remove screw-assembled lockwasher (11) and restriction solenoid lead (12) from receptacle (25).
Discard screw-assembled lockwasher (11).
2.
Remove nut-assembled lockwasher (22) and thermostat lead (21) from overheat switch (20).
Discard nut-assembled lockwasher (22).
3.
Remove screw-assembled lockwashers (15) and (16) and leads (17) and (13) from flame detector
switch (23). Discard screw-assembled lockwashers (15) and (16).
4.
Remove nut (14) and receptacle ground lead (24) from stud (19).
5.
Remove four screw-assembled lockwashers (10) and receptacle (25) from bracket (18). Discard
screw-assembled lockwashers (10).