TM 9-2320-361-24-2
0392 00
CHEMICAL AGENT ALARM MOUNTING KIT REPLACEMENT (Contd)
INSTALLATION
1.
Position detector unit bracket (1) on left front fender (8) and install with three screws (4),
support (9), and three new locknuts (10).
2.
Install harness receptacle (5) on bracket (2) with nut (3).
3.
Install harness (20) on left front fender (8) with clamp (7) and screw (6).
4.
Feed harness (20) into engine compartment.
5.
Install washer (14), ground strap (15), and harness ground wire (18) on right side of turn signal
flasher box (13) with screw (19), washer (12), and new locknut (11).
6.
Connect wire (16) to connector (17).
7.
Feed harness (20) along main wiring harness (27), under cab, along cab frame (35), and through
cab floor hole (36).
8.
Position alarm unit bracket (23) on rear cab panel (21) and install with two screws (24) and new
locknuts (22).
9.
Insert harness (20) through two clamps (26) and tighten screws (25).
10.
Install harness (20) on rear cab panel (21) with clamp (38) and screw (39).
NOTE
Assistant will help with steps 11 through 14.
11
Insert harness (20) in grommet (37) and install in cab floor hole (36).
12.
Install harness (20) on frame (35) with two clamps (34) and screws (33).
13.
Install harness (20) on main wiring harness (27) with four new tiedown straps (28).
14.
Install harness (20) on firewall (32) with clamp (29), screw (30), and new locknut (31).
15.
Install M43 detector and M42 alarm unit (TM 3-6665-225-12).
16.
Connect battery ground cable (WP 0126 00).
17.
Lower and secure hood (TM 9-2320-361-10).
18.
Release parking brake and remove wheel chocks (TM 9-2320-361-10).