TM 9-2320-361-24-2
0392 00
CHEMICAL AGENT ALARM MOUNTING KIT REPLACEMENT (Contd)
REMOVAL
1.
Remove nut (3) and harness receptacle (5) from bracket (2).
2.
Remove three locknuts (10), support (9), three screws (4), and detector unit bracket (1) from left
front fender (8). Discard locknuts (10).
3.
Remove screw (6) and clamp (7) from front fender (8).
4.
Disconnect wire (16) from connector (17).
5.
Remove locknut (11), washer (12), screw (19), harness ground wire (18), ground strap (15), and
washer (14) from right side of turn signal flasher box (13). Discard locknut (11).
6.
Remove four tiedown straps (28) from main wiring harness (27). Discard tiedown straps (28).
NOTE
Assistant will help with steps 7 through 13.
7.
Remove locknut (31), screw (30), and clamp (29) from firewall (32). Discard locknut (31).
8.
Loosen two screws (25) and remove harness (22) from clamps (26).
9.
Remove screw (39) and clamp (38) from rear cab panel (20).
10.
Remove grommet (37) from cab floor hole (36).
11.
Remove two screws (33) and clamps (34) from frame (35).
12.
Remove harness (22) from firewall (32).
13.
Remove two locknuts (21), screws (24), and alarm unit bracket (23) from rear cab panel (20).
Discard locknuts (21).
0392 00-2
|