Page Title: FILTER SEPARATOR MAINTENANCE (M49A2C) - continued
Back | Up | Next

Click here for a printable version

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

TM 9-2320-361-24-2
0286 00
FILTER SEPARATOR MAINTENANCE (M49A2C) (Contd)
WARNING
Diesel fuel is flammable. Do not perform fuel system procedures near open
flames. Injury or death to personnel may result.
Accidental or intentional introduction of liquid contaminants into the
environment is a violation of state, federal, and military regulations. Refer to
Army POL (WP 0001 00) for information concerning storage, use, and disposal
of these liquids. Failure to do so may result in damage to environment and
health of personnel.
NOTE
Use a drain pan to capture any draining fuel. Dispose of fluids in accordance
with local policy and ordinances. Ensure all spills are cleaned up.
REMOVAL
1.
Remove two nuts (19), screws (21), and coupling halves (18) from gasket (16) and filter
separator (11).
2.
Disconnect nipple (2) and air eliminator hose (1) from cover (3).
NOTE
Assistant will help with step 3.
3.
Remove four locknuts (17), screws (12), filter separator (11), and gasket (16) from separator
pipe (20) and shelf (13). Discard locknuts (17) and gasket (16).
DISASSEMBLY
1.
Remove nut (24), coupling clamp (25), cover (3), and gasket (23) from filter separator (11). Discard
gasket (23).
2.
Remove cotter pin (27) and vent valve (26) from cover (3). Discard cotter pin (27).
3.
Remove six nuts (4), three washers (5), and plate (6) from filter separator (11).
4.
Remove three nuts (7), screws (10), and washers (9) from filter separator brackets (8).
5.
Remove three canisters (14) and filter elements (15) and (22) from filter separator (11). Discard
filter elements (15) and (22).
CLEANING AND INSPECTION
WARNING
Skysol 100 solvent is combustible; DO NOT use or store near heat, sparks,
flame, or other ignition sources. Use mechanical ventilation whenever product
is used in a confined space, heated above ambient temperatures, or agitated.
Keep container sealed when not in use.
Contact with Skysol 100 may cause skin irritation. Use chemical-resistant
gloves. In case of skin contact, remove any contaminated clothing and wash
skin thoroughly with soap and water. Wash contaminated clothing before reuse.
Eye contact may cause irritation, tearing, or blurring of vision. Use face shield
or goggles when eye contact may occur. In case of eye contact, flush eyes with
large amounts of water for at least 15 minutes or until irritation subsides.
Inhalation may cause irritation to upper respiratory passages. DO NOT have
food or drink in the vicinity. Failure to comply may result in injury to
personnel.
1.
Clean canisters (14) and inside of filter separator (11) with Skysol 100 solvent.
2.
Inspect canisters (14) for cracks. Replace canisters (14) if cracked.