TM 9-2320-361-24-1
0183 00
AIR COMPRESSOR GOVERNOR MAINTENANCE (Contd)
REMOVAL
WARNING
Do not disconnect air lines before draining air reservoirs. Small
parts under pressure may shoot out with high velocity, causing
injury to personnel.
NOTE
Prior to removal, tag all air lines and hoses for installation.
1.
Remove two air lines (6) and (8) from tee fitting (7).
2.
Remove air line (4) from adapter (3).
3.
Remove two screw-assembled lockwashers (5) and air compressor governor (10) from firewall (2).
Discard screw-assembled lockwashers (5).
4.
Remove tee fitting (7), adapter (9), and adapter (3) from air compressor governor (10).
INSTALLATION
NOTE
Wrap all male pipe threads with antiseize tape before
installation.
1.
Install adapter (3) and adapter (9) on air compressor governor (10).
2.
Install tee fitting (7) on adapter (9).
3.
Install air compressor governor (10) on firewall (2) with two new screw-assembled lockwashers (5).
4.
Install air line (4) on adapter (3).
5.
Install two air lines (8) and (6) on tee fitting (7).
6.
Connect battery ground cable (WP 0126 00).
7.
Lower and secure hood (TM 9-2320-361-10).