TM 9-2320-361-24-1
0158 00
REAR SPRING MAINTENANCE (Contd)
DISASSEMBLY
NOTE
Some springs have two leaves and eight plates, and others
have two leaves and ten plates. Both types are maintained
the same way. This procedure covers the spring with eight
plates.
Only the two leaves of the spring can be replaced. Damaged
plates require replacement of whole spring.
1.
Position C-clamp on spring (2) near center bolt (6). Ensure C-clamp is vertically centered and
square across spring (2).
2.
Remove four nuts (1), screws (8), and spacers (7) from two long leaf clips (5) and short leaf
clips (4). Discard nuts (1) and screws (8).
WARNING
Leaves and plates of assembled spring are under tension.
Restrain all leaves and plates while removing center bolt.
Release tension slowly. Failure to do so may result in injury to
personnel.
3.
Remove nut (3) and center bolt (6) from spring (2). Discard center bolt (6) and nut (3).
4.
Slowly loosen C-clamp until tension on plates (19) and leaves (20) is released. Remove C-clamp
from spring (2).
5.
Using a center punch and drill, remove rivets (21) from two long leaf clips (5) and short leaf
clips (4). Discard rivets (21).
CLEANING AND INSPECTION
WARNING
Skysol 100 solvent is combustible; DO NOT use or store near
heat, sparks, flame, or other ignition sources. Use mechanical
ventilation whenever product is used in a confined space,
heated above ambient temperatures, or agitated. Keep
container sealed when not in use.
Contact with Skysol 100 may cause skin irritation. Use
chemical-resistant gloves. In case of skin contact, remove any
contaminated clothing and wash skin thoroughly with soap and
water. Wash contaminated clothing before reuse. Eye contact
may cause irritation, tearing, or blurring of vision. Use face
shield or goggles when eye contact may occur. In case of eye
contact, flush eyes with large amounts of water for at least 15
minutes or until irritation subsides. Inhalation may cause
irritation to upper respiratory passages. DO NOT have food or
drink in the vicinity. Failure to comply may result in injury to
personnel.
1.
Clean all parts with Skysol 100. Use wire brush to remove rust and corrosion. Dry with clean rag.
2.
Inspect plates (11) through (18) and leaves (9) and (10) for breaks and cracks. Replace leaves (9)
and (10) if broken or cracked. Broken or cracked plates require replacement of entire spring.
3.
Inspect long leaf clips (5), short leaf clips (4), and spacers (7) for cracks or breaks. Replace clips (5)
and (4) and spacers (7) if cracked or broken.