TM 9-2320-361-24-1
0139 00
PROPELLER SHAFT MAINTENANCE (Contd)
ASSEMBLY
1.
Install breather (2) in end of shaft tube (3).
NOTE
Perform step 2 if lubrication fitting was removed.
2.
Install lubrication fitting (10) in shaft tube (3).
3.
Install new seal (4) in bore (9) of shaft tube (3).
4.
Install cap (6) on shaft (7) with open side toward shaft end and slide up on shaft (7).
5.
Install washer (5) on shaft (7).
6.
Apply a thick film of GAA grease on splines of shaft (7).
7.
Slide splined end of shaft (7) through seal (4) and into internal splines of shaft tube (3).
8.
Position washer (5) against seal (4) and install cap (6) on shaft tube (3).
2
1
3
4
5
6
7
8
9
10