|
|
TM 9-2320-361-24-1
0137 00
TRANSFER CASE BREATHER MAINTENANCE (Contd)
REMOVAL
1.
Wipe area around transfer case breather (2) with rag.
2.
Remove transfer case breather (2) from transfer case (1).
CLEANING
WARNING
Skysol 100 solvent is combustible; DO NOT use or store near
heat, sparks, flame, or other ignition sources. Use mechanical
ventilation whenever product is used in a confined space,
heated above ambient temperatures, or agitated. Keep
container sealed when not in use.
Contact with Skysol 100 may cause skin irritation. Use
chemical-resistant gloves. In case of skin contact, remove any
contaminated clothing and wash skin thoroughly with soap and
water. Wash contaminated clothing before reuse. Eye contact
may cause irritation, tearing, or blurring of vision. Use face
shield or goggles when eye contact may occur. In case of eye
contact, flush eyes with large amounts of water for at least 15
minutes or until irritation subsides. Inhalation may cause
irritation to upper respiratory passages. DO NOT have food or
drink in the vicinity. Failure to comply may result in injury to
personnel.
Clean transfer case breather (2) with Skysol 100.
INSTALLATION
1.
Install transfer case breather (2) into transfer case (1).
2.
Install cab tunnels (WP 0230 00).
3
Connect battery ground cable (WP 0126 00).
4.
Release parking brake and remove wheel chocks (TM 9-2320-361-10).
2
1
END OF WORK PACKAGE
0137 00-2
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |