0128 00
TRANSMISSION BREATHER MAINTENANCE (Contd)
REMOVAL
1.
Wipe area around transmission breather hole (2) with rag.
2.
Remove transmission breather (1) from transmission housing (3).
CLEANING
WARNING
Skysol 100 solvent is combustible; DO NOT use or store near
heat, sparks, flame, or other ignition sources. Use mechanical
ventilation whenever product is used in a confined space,
heated above ambient temperatures, or agitated. Keep
container sealed when not in use.
Contact with Skysol 100 may cause skin irritation. Use
chemical-resistant gloves. In case of skin contact, remove any
contaminated clothing and wash skin thoroughly with soap and
water. Wash contaminated clothing before reuse. Eye contact
may cause irritation, tearing, or blurring of vision. Use face
shield or goggles when eye contact may occur. In case of eye
contact, flush eyes with large amounts of water for at least 15
minutes or until irritation subsides. Inhalation may cause
irritation to upper respiratory passages. DO NOT have food or
drink in the vicinity. Failure to comply may result in injury to
personnel.
Clean transmission breather (1) with Skysol 100 solvent.
INSTALLATION
1.
Install transmission breather (1) on transmission housing (3).
2.
Install cab intermediate tunnel (WP 0230 00).
3.
Connect battery ground cable (WP 0126 00).
4.
Release parking brake and remove wheel chocks (TM 9-2320-361-10).
1
2
3
END OF WORK PACKAGE