TM 9-2320-361-24-1
0126 00
BATTERY CABLES AND CLAMPS MAINTENANCE (Contd)
REMOVAL
Ground Cable
1.
Remove nut (19) and screw (29) and disconnect ground cable (21) from battery clamp (20).
2.
Remove nut (13), lockwasher (14), ground cable (21), lockwasher (17), and screw (16) from
frame (15). Discard lockwashers (14) and (17).
Battery-to-Battery Cable
1.
Remove nut (25), screw (2), and cable (1) from negative clamp (4).
2.
Remove nut (27), screw (24), and cable (1) from positive clamp (22).
Positive Cable
1.
Remove nut (7) and screw (9) and disconnect positive cable (5) from battery clamp (6).
2.
Remove nut (35) and disconnect positive cable (5) and wire (34) from starter solenoid (33).
3.
Remove screw (31), clamp (32), and positive cable (5) from frame (15).
Battery Clamps
1.
Remove two nuts (26) and (18), screws (3) and (30), and clamps (4) and (20) from two negative
posts (12).
2.
Remove two nuts (8) and (28), screws (10) and (23), and clamps (6) and (22) from two positive
posts (11).