TM 9-2320-361-24-1
0090 00
WIRING HARNESS CONNECTOR REPAIR (Contd)
MALE CABLE CONNECTOR REPAIR
1.
Strip cable insulation (1) from cable (2) to equal depth of terminal well (5).
2.
Slide shell (3) and slotted washer (4) over cable insulation (1).
3.
Insert cable (2) into terminal well (5) and crimp.
4.
Place slotted washer (4) over crimped junction at terminal (6).
5.
Slide shell (3) over slotted washer (4) and terminal (6).
3
4
5
6
1
2
FEMALE CABLE CONNECTOR REPAIR
1.
Strip cable insulation (7) from cable (8) to equal depth of terminal well (11).
2.
Slide shell (9) and sleeve (10) over cable insulation (7).
3.
Insert cable (8) into terminal well (11) and crimp.
4.
Slide sleeve (10) and shell (9) over terminal (12).
9
11 12
10
7
8
0090 00-2
|