TM 9-2320-361-24-1
0023 00
PREVENTIVE MAINTENANCE CHECKS AND SERVICES (PMCS) (Contd)
Table 1. Preventive Maintenance Checks and Services (PMCS) (Contd).
ITEM
ITEM TO CHECK/
EQUIPMENT NOT
INTERVAL
PROCEDURE
NO.
SERVICE
READY/AVAILABLE IF:
Semiannually Air cleaner
c. Using a piece of wood, cover
indicator
approximately 90 percent of air cleaner
(Contd)
opening.
d. Observe the air cleaner indicator (1) to
Semiannually
see if yellow band is visible. If yellow
band is visible, air cleaner indicator (1)
is working properly. If not, air cleaner
indicator (1) is defective or indicator
tube is obstructed. Stop engine
(TM 9-2320-361-10).
Semiannually
e. Remove wood and install cap on air
cleaner with clamp.
1
10
Biennially
Data, caution,
Inspect for completeness, security, and
and warning
readability. Replace if necessary.
plates
ENGINE COMPARTMENT
WARNING
If NBC exposure is suspected, all air filter
media must be handled by personnel
wearing protective equipment. Consult
your unit NBC officer or NBC
noncomission officer for appropriate
handling and disposal instructions.
Failure to do so may result in injury to
personnel.
NBC contaminated filters must be
handled using adequate precautions
and must be disposed of by trained
personnel. Failure to do so may result in
injury to personnel.
NOTE
Open hood and secure with retaining
latch (TM 9-2320-361-10).
0023 00-5