TM 9-2320-361-24-1
0014 00
INDICATORS, GAUGES, AND WARNING SYSTEM TROUBLESHOOTING (Contd)
Table 1. Indicator, Gauges, and Warning System Troubleshooting (Contd).
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
Test 4. Test continuity of lead 28.
3. FUEL GAUGE
1. Turn power accessory switch
INOPERATIVE
to OFF position.
(Contd)
2. Disconnect lead 28 from fuel
gauge and from fuel level
sending unit.
3. Connect jumper wire from
fuel level sending unit end of
lead 28 to frame ground.
4. Set multimeter to RX 1 scale.
5. Connect negative lead of
1. If continuity is present, reconnect
multimeter to frame ground
lead 28 and recheck fuel gauge
and touch positive lead of
operation.
multimeter to contact of
2. If continuity is not present, repair
or replace wiring (WP 0090 00).
lead 28.
Test 5. Test continuity of fuel level
sending unit.
1. Set multimeter to RX 1 scale.
2. Connect multimeter leads to
fuel sending unit.
1. If resistance is 0.000.50 ohms, go
3. Position float in empty
to step 4.
position.
2. If resistance is not 0.000.50 ohms,
4. Set multimeter to RX 10 scale.
replace fuel sending unit
1. If resistance is 29.5031.50 ohms,
5. Position float in full position.
reinstall fuel level sending unit
operation.
2. If resistance is not 29.5031.50 ohms,
replace fuel level sending unit.
FUEL LEVEL
SENDING UNIT
TEST 1
TEST 5
STEP 3
STEPS 3
AND 5
28
FUEL
GAUGE
TEST 4
STEP 5
0014 00-7
|