TM 9-2320-361-24-1
0013 00
LIGHTING AND WIPER SYSTEM TROUBLESHOOTING (Contd)
Table 3. Directional Signal Systems Troubleshooting Procedures (Contd).
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
Test 2. Test for voltage at front
1. DIRECTIONAL
composite light.
SIGNAL
INOPERATIVE
1. Disconnect lead 461 at left
(Contd)
front composite light.
2. Place turn signal lever in left
position.
3. Set multimeter to range that
will measure 24 volts.
4. Touch multimeter negative
lead to frame ground.
5. Touch multimeter positive lead
1. If voltage does fluctuate, go to
to contact end of lead 461.
test 3.
Voltage should fluctuate at
2. If voltage does not fluctuate, go to
rate of 1 or 2 cycles per second.
test 4.
Test 3. Test continuity of filament and
1. If continuity is present, reconnect
socket for turn signal lamp.
leads 460-461 and check turn signal
Check continuity between lead
operation. If turn signal operates
460-461 attached to front
but does not flash, go to tests 6
composite light and frame
and 7.
ground.
2. If continuity is not present, replace
turn signal lamp (WP 0122 00).
MAL 1
TEST 2
STEPS 4 AND 5
49
1
491
460/461
46
1
20
20
MAL 1
TURN SIGNAL
TEST 3
LIGHT
0013 00-13
|