TM 9-2320-361-24-1
0012 00
BATTERY AND CHARGING SYSTEM TROUBLESHOOTING (Contd)
Table 2. Starting System Troubleshooting Procedure (Contd).
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
3. With engine stop control
1. If battery voltage is not
2. STARTER MOTOR
handle pulled out, crank
satisfactory, go to WP 0012 00,
OPERATES, BUT
engine for 30 seconds
table 1, malfunction 1, test 1.
ENGINE CRANKS
(TM 9-2320-361-10). Voltage
SLOWLY (Contd)
2. If battery voltage is satisfactory,
reading should be 19 VDC or
replace starter motor and solenoid
more during cranking.
assembly (WP 0088 00).
4. Disengage engine stop control
If engine still cranks slowly, replace
handle (TM 9-2320-361-10).
batteries (WP 0127 00).
CHARGING SYSTEM (60 AMP)
START
SWITCH
B
74B
74A
A
74
D
C
STARTER
B
A
B
27
27
D
INPUT FIELD VOLTAGE
1
+28 VDC OUTPUT
STARTER
10
C
14
1
214
11
A
15-AMP
1
4
HORN
POS
2
CIRCUIT
568
3
2
NEG
BREAKER
6
49
POWER
ACCESSORY
60-AMP
SWITCH
68
25
SLAVE
50
RECEPTACLE
7
12-VOLT
STARTER
BATTERY
MOTOR
RH GROUND FRAME
0012 00-18
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |