Click here to make tpub.com your Home Page

Page Title: POWER PLANT HEATER REMOVAL, REPAIR, AND REPLACEMENT - continued
Back | Up | Next

Click here for a printable version

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

TM 9-2320-209-34-2-3
FRAME 7
NOTE
Put gasket (1), orifice plate (2), and gasket (3) on cover
plate (4) exactly as shown.  Put orifice plate and gasket
assembly (5) on fuel control valve (6) exactly as shown.
Put new gasket (1), orifice plate (2), and new gasket (3) on cover plate (4).
1.
Put orifice plate and gasket assembly (5) on fuel control valve body (6).
2.
Put thermostat (7) and clamp (8) on orifice plate and gasket assembly (5).
3.
Screw in three screws (9) finger tight.
4.
Tighten three screws evenly,
tightening each one a little at a time.
5.
Slide two electrical leads (10) on terminals of thermostat (7).
Do frame 2 again if fuel control valve did not pass fuel flow test. If fuel
6.
control valve still does not pass fuel flow test, get new fuel control valve.
END OF TASK
21-44

Privacy Statement - Press Release - Copyright Information. - Contact Us

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business