TM 9-2320-209-34-2-3
FRAME
2
1.
Tag blower motor electrical lead (1) . Unscrew and take out terminal
screw (2). Take off blower motor electrical lead (1).
2.
Tag terminal screw (2) the same as blower motor electrical lead (1). Screw
in terminal screw (2).
3.
Scratch a line (3) across blower assembly (4) and housing (5). Loosen
four nuts (6) around blower assembly (4).
Turn blower assembly (4) so slots (7) clear studs (8). Take off blower
4.
assembly (4).
GO TO FRAME 3
21-19
|