TM 9-2320-209-34-2-3
FRAME
1
NOTE
If fuel control valve (1) is already off heater, skip
step 1.
Refer to para 21-6c, frame 1, frame
1.
Take fuel control valve (1) off heater.
4, and frame 5.
2.
Connect fuel supply line (2) to fuel inlet fitting (3).
Using a suitable electrical lead (4), connect shutoff electrical lead (5) and
3.
restrictive electrical lead (6) together. Connect other end of lead (4) to
pin B (7) of wiring harness connector (8).
Using another suitable electrical lead (9), connect body of fuel control
4.
valve (1) to pin A ( 10) of wiring harness connector (8).
GO TO FRAME 2