TM 9-2320-209-34-2-2
1.
Working through boring case inspection hole (1), mount dial indicator on
housing and set stem against side of rack drive gear tooth (2) as shown.
NOTE
When measuring backlash, make sure second reduction
drive pinion (3) does not turn. If pinion turns, back-
lash readings will be wrong.
Turn rack drive gear (4) away from dial indicator until rack drive gear
2.
tooth (5) touches pinion tooth (6) as shown in view A.
3.
Set dial indicator to read 0.
4.
Turn rack drive gear (4) toward dial indicator until rack drive gear tooth
(7) reaches other side of pinion tooth (6) as shown in view B. Note reading
on dial indicator.
IF READING ON DIAL INDICATOR IS NOT BETWEEN .008 TO .030 INCH, GO TO
FRAME 7.
IF READING ON DIAL INDICATOR IS BETWEEN .008 TO .030 INCH, GO TO
FRAME 8
17-519
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |