TM 9-2320-209-34-2-2
FRAME 4
Open intake gate valve (1) and outlet gate valve (2).
1.
2.
Turn on motor (3) and run at 540 RPM. Adjust valve setscrew on discharge
part of pump (4) until pressure gage (5) reads 45 psi.
Turn down motor speed until pressure at gage (5) is 40 psi.
3.
Read flow on flow meter (6).
Send back pump if flow is less than 52 GPM.
4.
5.
Listen to pump while it is running.
Send back pump if vane hoist is too
high.