(2) Cleaning, inspection, and repair.
WARNING
Dry cleaning solvent is flammable. Do not use near an
open flame. Keep a fire extinguisher nearby when sol-
vent is used. Use only in well-ventilated places.
Failure to do this may result in injury to personnel and
damage to equipment.
1. Clean pushrod (1), snapring (2), snapring collar (3), pressure plate (4), cup
expander (5), and follower (6) with dry cleaning solvent.
2. Check that pushrod (1) has no nicks or scratches. Rub out small scratches with
crocus cloth. If more repair is needed, throw away pushrod and get a new one.
3. Check that pressure plate (4) and follower (6) have no nicks or scratches. Rub
out small scratches with crocus cloth. If more repair is needed, throw away air
hydraulic cylinder and get a new one.
4. If cup expander (5) is broken or damaged, throw it away and get a new one.
END OF TASK