TM 9-2320-209-20-3-3
FRAME 3
WARNING
When unscrewing the last of four capscrews (1) hold
pump (2) so that it does not fall and cause injury.
1. Using 9/16-inch wrenches, unscrew and take off four capscrews and self-
locking nuts (1). Move pump (2) away from universal joint (3), making
sure key (4) does not get lost.
2. Tape key (4) to pump shaft (5) so it will not be lost.
GO TO FRAME 4
18-461
|