TM
9-2320-209-20-3-3
FRAME 3
Soldier A 1.
Put discharge valve gasket (1) between discharge valve (2)
and discharge pipe (3), alining holes.
Soldier B 2.
Put in six cap screws (4).
Using 9/16-inch wrench, hold
capscrews.
Soldier A 3.
Put on six washers (5). Using 9/16-inch socket, extension,
universal joint, and ratchet, screw on and tighten six nuts (6).
GO TO FRAME 4