FRAME 2
1.
Using putty knife, clean flanges of plate (1) and automatic dump valve
housing (2).
WARNING
Dry cleaning solvent is flammable. Do not use near
an open flame.  Keep a fire extinguisher nearby when
solvent is used.  Use only in well-ventilated places.
Failure to do this may result in injury to personnel
and damage to equipment.
2.
Using solvent, clean automatic dump valve housing (2) and all parts of
automatic dump valve assembly (3).
Check that float (4) can move up and down freely.
3.
4.
Check that moving parts of automatic dump valve assembly (3) are not worn
or damaged.  Get new parts if needed.
Put a coating of liquid gasket cement of flanges of automatic dump valve
5.
housing (2) and plate (1).
Place gasket (5) on plate (1) and aline holes.
6.
Put plate (1) with gasket (5) to automatic dump valve housing (2) as noted.
7.
8.
Using wrench, screw in and tighten eight screws (6).
END OF TASK