TM 9-2320-209-20-3-1
FRAME 5
1.
Push lockout arm (1) up until shoulder bolt (2) is firmly seated at bottom of
slot in lockout arm, locking transfer in neutral.
2.
While holding lockout arm (1) up, check alinement of holes in clevis (3) with
hole in lockout shaft lever (4).
If holes do not line up, do steps 4 and 5 to shorten or lengthen control rod (5).
3.
4.
Using 5/8-inch wrench, loosen jamnut (6).
5.
Screw control rod (5) into clevis (7) to shorten control rod. Unscrew control
rod (5) from clevis (7) to make control rod longer.
IF CONTROL ROD (5) CANNOT BE MADE LONG ENOUGH TO ALINE HOLES,
GO TO FRAME 6.
IF CONTROL ROD (5) CAN BE ADJUSTED TO ALINE HOLES, GO TO FRAME 7
9-20
|