FRAME 4
1.
Using mechanical puller (1), set adjustable arms (2) of puller over rear edge of
generator pulley (3) as shown.
2.
Screw puller bolt (4) in until it presses against generator shaft (5) as shown.
Using 3/4-inch socket wrench, slowly tighten puller bolt (4) until generator
3.
pulley (3) is loose on shaft (5).  Pulley will move in direction shown.
Take puller (1) off generator pulley (3) and slide pulley off end of shaft (5).
4.
Tape key (6) to shaft (5) so it will not be lost.
5.
END OF TASK