Hold thermostat housing (1) firmly against intake manifold (2).
Screw in two bolts (3) with flat washers (4) through thermostat housing (1)
2.
and into intake manifold (2). Using 9/16-inch Wrench, tighten bolts evenly.
Put clamp (5) squarely over hose (6) as shown.
3.
Using screwdriver, tighten screw (7) on clamp (5).