TM
9-2320-209-20-3-1
FRAME 3
1.
Using spring scale (l), pull upper end of bar (2) with force of 50 pounds and using
9/16-inch wrench, tighten capscrew (3). Take out bar.
2.
Push on belts (4) at point midway between coolant pump pulley (5) and generator
pulley (6). Belt should give about 3/4-inch at this point.
NOTE
Follow-on Maintenance Action Required:
Close hood. Refer to TM 9-2320-209-10.
END OF TASK