TM 9-2320-209-20-3-1
I
FRAME 2
Put cover (l) over four studs (2) and seat cover firmly on gasket (3).
1.
NOTE
Some pumps use three studs (2) to mount terminal cover(l).
Put four lockwashers (4) onstuds (2) and screw on four nuts (5). Using wrench,
2.
tighten nuts.
Thread end of wire on metallic seal (6) through hole in end of one stud (2). Thread
3.
end of wire back into metallic seal and squeeze seal using lead seal press.
Join connector (7) to receptacle (8).
4.
NOTE
Follow-on Maintenance Action Required:
Start truck and let engine run. Refer to TM 9-2320-209-10.
END OF TASK
TA